ISO 9001:2015 Certified Sole Teksan Distributor — SL & Maldives
Teksan Generators Sri Lanka · Sole Distributor · Since 1942

Teksan Generators Sri Lanka — Cummins, Perkins, Baudouin & Mitsubishi engines. Sole distributor.

From 10 kVA standby for a clinic to 3,500 kVA prime for an industrial campus — Teksan gensets engineered in Istanbul, packaged with Cummins, Perkins, Baudouin or Mitsubishi engines and Stamford or Leroy Somer alternators. Sole authorised distributor for Sri Lanka and the Maldives — sold, installed, commissioned and serviced by NativeWay.

10 — 3,500 kVA · 250+ models
24/7 emergency service · island-wide
UL2200 · ISO 8528 · EPA Tier 4
Teksan In Stock

Brand-new Teksan units available now.

20 to 200 kVA Teksan generators ready for Sri Lanka delivery. Authorised distributor, factory warranty.

View available stock
Founded
1994

Three decades of uninterrupted-power engineering.

Reach
140+

Countries on six continents.

Capacity
15,000

Generators built per year across 70,000 m² of plant.

Range
9 — 3,500

kVA single-set · 250+ models · 8 engine partners.

Power tiers

Right-sized power, picked by an engineer — not a salesman.

We start with your load profile, runtime expectation and site constraints, then specify the right unit. Three broad tiers cover most projects.

9 – 200 kVA

Small Commercial

Standby for shops, clinics, branch offices, small factories and residential developments.

  • Acoustic canopy · 70 dBA @ 7 m
  • Auto start / stop with ATS
  • Bunded fuel tank · 8 – 12 hr runtime
  • Battery charger & jacket-water heater standard
Get Sized & Quoted
1.5 – 3.5 MW

Prime & Industrial

Prime power for grid-disconnected sites, large hospitals, telecom, data centres and industrial campuses.

  • MV (11kV / 33kV) options
  • Synchronisation & load-share
  • Bi-fuel and HFO options
  • Custom enclosures & acoustic treatment
Engineering-Led Spec
Anatomy of a genset

A combination of engines and alternators — chosen for the job.

Teksan generators are built around three main components: an engine, an alternator and a controller. We pair world-class brands across each — so the unit fits your commercial level, runtime profile and load type.

Engines

The prime mover.

The heart of every genset. Teksan units are paired with four world-class diesel engines, sized to your load.

Perkins diesel engine
Perkins
UK
Cummins diesel engine
Cummins
USA
Mitsubishi Heavy Industries diesel engine
Mitsubishi HI
Japan
Baudouin diesel engine
Baudouin
France
Alternators

Where mechanical becomes electrical.

Coupled to the engine, the alternator turns shaft motion into clean three-phase AC.

Stamford AvK alternator
Stamford | AvK
UK
Leroy-Somer alternator
Leroy-Somer
France
Controllers

The brain.

Monitoring, automatic transfer and BMS / SCADA integration — configured to your facility.

Teksan TJ 509-T controller
Teksan TJ 509-T
Native
Deep Sea Electronics controller
Deep Sea Electronics
UK
Open · Skid · Mounted

Same engineering. Stripped to the essentials.

When the genset lives indoors — in a plant room, basement bay, or purpose-built acoustic enclosure — the canopy comes off. The same Perkins · Cummins · Mitsubishi · Baudouin core, the same Stamford / Leroy Somer alternator, the same DSE or Teksan controller — exposed for service access and integrated with the building's own ventilation and silencing.

  • Plant-room ready  ·  matched to building HVAC + acoustic design
  • Service-first geometry  ·  full 360° access to filters, batteries, control panel
  • 10 – 3,500 kVA  ·  same tier coverage as canopied units
  • EPA & UL2200  ·  identical certification path · FAT witnessed at Istanbul plant
Teksan open skid-mounted diesel generator
Teksan canopied diesel generator with brand mark visible on the enclosure
"Continuous development and innovation — uninterrupted energy solutions for a sustainable life."
— Teksan engineering principle
About Teksan

An engineering and technology company. Not just a generator brand.

Teksan began in 1994 in Istanbul. Today it engineers uninterrupted-energy solutions across diesel, natural gas, biogas, cogeneration, hybrid systems, mobile lighting and microgrids — deployed in 140+ countries.

Prime movers from Perkins, Cummins, Mitsubishi and Baudouin — coupled to Leroy Somer and Stamford alternators on UL2200-listed, EPA-certified production lines.

Perkins Cummins Mitsubishi Baudouin
70,000 m²
Indoor manufacturing
15,000 / yr
Annual production
250+
Generator models
9 — 3,500
kVA single-set range
At a glance

A specification you can hand straight to your consulting engineer.

We sell, install, commission and service the full Teksan range under a single point of contact. Below is the spec sheet our power engineers work from when sizing your unit — share it with your MEP consultant, or send us your load schedule and we'll mark it up for you.

Product range
9 kVA — 3,500 kVA single-set paralleled for higher
Engine partners
Perkins · Cummins · Mitsubishi · Baudouin
Alternator
Leroy Somer · Stamford Class H insulation, IP23 standard
Duty rating (ISO 8528-1)
ESP · LTP · PRP · COP specify at order
Transient class (ISO 8528-5)
G2 standard · G3 available for UPS / medical / data-centre loads
Voltage / frequency
400 V / 50 Hz / 3-ph standard · 6.6 / 11 / 33 kV MV options 230 V 1-ph below 20 kVA on request
Fuel
Diesel · Natural gas · Biogas · Bi-fuel · HFO on large units
Configuration
Open-skid · Acoustic canopy · Containerised · Mobile
Control panel
Teksan TJ 509-T · DeepSea DSE7320 MKII · DSE8610 MKII Modbus RTU / TCP, SNMP, BACnet on request
Standard fit
Battery charger · Jacket-water (block) heater · ATS-ready 2-wire start · Bunded base fuel tank · Anti-vibration mounts
Acoustic
Canopy units 70 dB(A) @ 7 m standard · super-silent option 65 dB(A) @ 7 m per-model 1 m / 7 m / octave-band data on request
Fuel runtime
8–24 hours at 75% load on bunded base tank model-dependent — external bulk tank available
Site derating
40 °C ambient, 1,000 m altitude reference; further derating per ISO 3046 for higher sites
Warranty
12 months or 1,000 hours, whichever first extendable to 24 months under AMC
Compliance
UL2200 Listed · US EPA Certified · EU Stage V · ISO 8528 · IEC 60034-1
UL2200
Listed
US EPA
Certified
EU Stage V
Emissions
ISO 8528
Genset standard
ISO 9001
Quality mgmt
ISO 14001
Environmental
Data for your consulting engineer

The numbers behind the brochure.

Sample data tables that consulting engineers and tender writers ask for. Per-model datasheets — with octave-band sound, full fuel-consumption curves and dimensional GA drawings — are issued on request once we know your unit.

ISO 8528-1 duty ratings — and what the same 500 kVA Teksan delivers under each

Rating Hours / year Load profile Overload allowance Typical use
ESP
Emergency Standby
< 200 hr Variable, avg ≤ 70% None Hotels, offices, commercial backup
LTP
Limited Time
< 500 hr 100% continuous None Utility peak-shaving, scheduled outages
PRP
Prime
Unlimited Variable, avg ≤ 70% 10% for 1 hr / 12 hr period Off-grid sites, construction camps, telecom towers
COP
Continuous
Unlimited 100% constant None Base-load on isolated grids, IPP / cogen

Rule of thumb: a 500 kVA-ESP set is the same machine as a ~450 kVA-PRP set. Always specify the rating you need at order — uprating an installed machine is rarely practical.

Sample diesel consumption — Teksan canopy units (litres / hour)

Model class 25% load 50% load 75% load 100% load Base tank
100 kVA standby ~7 l/hr ~13 l/hr ~18 l/hr ~24 l/hr 200 L · 11 hr@75%
250 kVA standby ~17 l/hr ~32 l/hr ~46 l/hr ~61 l/hr 500 L · 11 hr@75%
500 kVA standby ~33 l/hr ~63 l/hr ~91 l/hr ~122 l/hr 990 L · 11 hr@75%
1,000 kVA standby ~64 l/hr ~124 l/hr ~182 l/hr ~244 l/hr 1,800 L · 10 hr@75%
2,000 kVA standby ~130 l/hr ~250 l/hr ~365 l/hr ~490 l/hr External bulk · sized to runtime spec

Note: Indicative figures for engine-platform planning only. Per-model fuel curves vary ±5% with engine OEM, ambient and load type. Request a unit-specific datasheet for tender or LCA submissions.

Controllers — choose the brain to match your operations

Entry / Single-set

DeepSea DSE6020 / TJ 509-T

  • Auto-start, AMF, instrumentation, basic protections
  • Engine-OEM CAN J1939 interface
  • USB / RS232 for service tooling
  • Best for: single standby up to ~250 kVA, no remote monitoring required
Mid-range / Comms

DeepSea DSE7320 MKII

  • Configurable I/O, scheduled exercise runs, fuel-trip monitoring
  • Modbus RTU / Modbus TCP / SNMP — BMS integration
  • DSE WebNet remote monitoring (cellular / Ethernet)
  • Best for: 100 kVA–1 MW commercial standby tied into BMS / SCADA
Sync & paralleling

DeepSea DSE8610 MKII

  • Auto-synchronisation, kW & kVAr load-share across up to 32 sets
  • Mains paralleling, soft transfer, dead-bus arbitration
  • Modbus / SNMP / BACnet — full SCADA exposure
  • Best for: N+1 redundancy, hospitals, data centres, MV power plants
Per-model datasheet

Need the full spec sheet for tender submission?

We'll issue a stamped, unit-specific datasheet — model, engine OEM curve, alternator class, dimensional GA, fuel curve, sound octave-band, ATS schedule — within 24 hours.

Request datasheet
Beyond diesel

Five fuel paths. Pick the one that matches your fuel logistics and emissions targets.

Diesel is the workhorse — but Teksan's product line covers gas, biogas, hybrid and mobile solutions. We'll match the technology to your site.

D
Diesel

The standby and prime-power workhorse. 9 kVA – 3,500 kVA, UL2200 / EPA / EU Stage V across the range.

G
Natural gas

Lower running cost on piped-gas sites. PSI engines, EPA-certified, ideal for continuous and prime applications.

B
Biogas

Closed-loop power on landfill, agricultural and waste-to-energy sites. Tailored gas-train and conditioning packages.

C
Cogeneration

Combined heat & power. Up to 90% energy efficiency by capturing waste heat from natural-gas / biogas units.

H
Hybrid & mobile

Diesel + battery / solar microgrids, twin generators, towable rental sets, mobile lighting towers for project sites.

From inquiry to handover

What it's like to buy a generator from us.

A predictable five-step process — engineered, not improvised.

01
Load study

Capture load schedule, runtime, redundancy, site constraints.

02
Specification

Sized recommendation · written budget.

03
Manufacture & FAT

Build at Teksan plant · witnessed factory acceptance test.

04
Install & commission

Civil, ATS, fuel, exhaust, acoustic, cabling · SAT with load-bank.

05
AMC & lifecycle

Training, AMC, scheduled maintenance, 24/7 emergency response.

Service & support

The generator is just the start. The 24/7 support is what you're really buying.

Critical-power buyers don't choose a generator brand — they choose a service organisation. Here's what comes with us.

24/7 emergency response

Direct-line for AMC clients · 4-hour target response, island-wide.

Local parts inventory

Critical spares stocked in Colombo. No 3-week shipping waits.

AMC contracts

Quarterly PM, oil/filter, load-bank tests — single annual fee.

Remote monitoring

SCADA / IoT · fault alerts, fuel level, run hours streamed to BMS.

Compliance documentation

Test certificates, DMMC/CEB docs, environmental reports, as-builts.

Operator training

Hands-on training for your facility team — not just keys and a manual.

Ready to spec a unit?

Tell us your load. We’ll size it and respond with an engineering-led proposal.

Send us your load schedule. A power engineer will come back with a sized recommendation and a budget number.